Micro air quality monitoring stations (micro stations) are widely used in scenarios like urban refined air quality monitoring and pollution source tracing, thanks to their advantages of flexible deployment, low cost, and grid-based coverage. However, they face numerous pain points in practical application, rooted in the inherent conflict between "miniaturization" and "high precision, high reliability". Here’s a detailed breakdown of the key challenges:
- Insufficient Data Accuracy and Stability
Limited Intrinsic Sensor Performance
Most micro stations adopt low-cost electrochemical sensors and laser scattering sensors, which have significant precision gaps compared to sophisticated analytical instruments in standard stations (e.g., β-ray method for PM2.5, gas chromatography for VOCs). For example:
- Electrochemical gas sensors (for NO₂, SO₂, etc.) are susceptible to temperature, humidity, and cross-gas interference (e.g., NO₂ sensors are sensitive to O₃). They tend to saturate under high-concentration pollution, with errors exceeding ±20%.
- Laser particle sensors, without preprocessing, show 30%-50% higher measurements in high-humidity environments (>85% RH) due to particle hygroscopic expansion. Long-term use leads to increased drift (5%-10% per month) from dust accumulation on optical components.
- Some low-cost micro stations lack temperature and pressure compensation modules, resulting in over 15% deviation in gas concentration measurements when the environment fluctuates by 10℃.
Short Calibration Cycles and High Difficulty
Micro station sensors drift much faster than those in standard stations: electrochemical sensors require monthly calibration, and laser particle sensors need calibration every 3 months. However, due to cost constraints in actual operation and maintenance (O&M), most users fail to meet these requirements. For instance, in a municipal grid monitoring project, 60% of micro stations had PM2.5 data deviations exceeding 40% from standard stations after 3 months without timely calibration, losing reference value. Additionally, calibration requires professional equipment (e.g., standard gas generators, aerosol generators), with a single calibration cost of ~$30-$75 per unit. For 1,000 stations, the annual calibration cost can reach hundreds of thousands of dollars, exceeding the affordability of small-scale users.
Poor Representativeness of Single-Point Data
The small size of micro stations makes their installation location a critical factor in data accuracy:
- Proximity to trash bins or restaurant exhaust vents leads to abnormally high VOCs and particle readings.
- Installation under tree shade or leeward building sides may underestimate pollutant concentrations due to poor air circulation.
In a community monitoring project, three micro stations within 50 meters of the same area showed 20-30μg/m³ differences in hourly average PM2.5 values due to different installation locations (roadside/roof/green belt), failing to reflect the true regional air quality.
- Weak Environmental Adaptability, Prone to Failure in Extreme Scenarios
Sharp Reliability Decline in Severe Weather
- High temperatures (>40℃) accelerate electrolyte evaporation in electrochemical sensors, shortening their lifespan from 1 year to 3-6 months.
- Low temperatures (<-10℃) cause laser particle sensor pumps to stop, interrupting data collection.
- Heavy rain or high humidity can lead to water ingress and short circuits in unprotected sensors. Even with basic waterproofing, condensation on optical lenses may trigger false "off-the-chart" particle readings.
- Sandstorms and salt spray (in coastal/industrial areas) can block sensor air inlets or corrode circuits. After a typhoon in a coastal city, 30% of micro stations failed to start due to salt spray erosion.
Significant Electromagnetic and Vibration Interference
- Micro stations deployed near substations, high-voltage lines, or busy roads are prone to electromagnetic interference, causing data jumps (e.g., NO₂ instantaneous values spiking from 50μg/m³ to 200μg/m³).
- Vibration near construction sites or subway lines shifts the optical path of laser sensors, expanding measurement errors. At a subway-adjacent monitoring point, PM10 data was 20%-30% higher during the day (when subways are operational) than at night, showing obvious "false fluctuations".
- High Operation and Maintenance Costs
Frequent Consumable Replacement and Maintenance
Vulnerable components of micro stations (e.g., particle sensor filters, photoionization sensor UV lamps) require regular replacement:
- Filters need replacement every 1-2 months (to avoid air inlet blockage).
- Electrochemical sensors typically have a 1-2 year lifespan.
The annual consumable cost per unit is ~$75-$150. For 1,000 stations, the annual O&M cost exceeds $75,000, far exceeding the "low-cost" expectation. Additionally, manual maintenance is inefficient: a single technician can maintain only 20 stations per day (including cleaning, calibration, and consumable replacement). For grid-based stations scattered across cities, commuting time accounts for over 60% of the total, resulting in extremely low actual efficiency.
Difficult Fault Diagnosis and Localization
Common micro station faults (e.g., communication interruptions, abnormal data) are mostly hidden:
- Sensor "freezing" may only manifest as unchanging data rather than complete offline status, requiring comparison with historical trends to detect.
- Data disconnection due to SIM card arrears or weak signals requires on-site inspections one by one, which is time-consuming and labor-intensive.
In one project, 10% of "data missing" cases were actually sensor faults. Failure to detect them in a timely manner rendered 1 month of data invalid.
- Restrictions on Data Transmission and Application
Poor Data Transmission Stability
Most micro stations rely on 4G/5G or LoRa for data transmission. In remote areas (e.g., suburbs, mountainous regions), weak signals cause data delays (hours or even 1 day). Some stations experience "data jumps" (e.g., repeated uploads of instantaneous values) due to operator base station switching. In a county-level monitoring project, the data integrity rate of mountainous stations was only 60%-70%, making them unusable for pollution trend analysis.
Data Homogenization and Difficult Interpretation
- Most micro stations only monitor 6 conventional parameters (PM2.5, PM10, SO2, NO2, O3, CO) and lack coverage of characteristic pollutants (e.g., VOCs components, heavy metals), making it difficult to support pollution source tracing (e.g., distinguishing industrial waste gas from automobile exhaust).
- Meanwhile, data contains much noise (e.g., instantaneous pulse values) that requires algorithmic filtering. However, micro stations have limited computing power (mostly low-end MCUs) and cannot run complex filtering models, leading to platform-side processing of large amounts of invalid data and increased analysis costs.
Lack of Standards Limits Application
Currently, there are no unified domestic technical standards for micro stations (e.g., sensor precision, calibration methods, data validity determination). Data from equipment of different manufacturers varies significantly (e.g., O3 measurements of Brand A are 30% higher than Brand B), making regional comparisons difficult. Environmental protection departments usually only use micro station data as "reference" and do not include it in official releases or law enforcement bases, limiting its practical value in environmental management.
- Hidden Constraints on Power Supply and Installation
Power Supply Limits Deployment Scenarios
- Mains power supply requires proximity to utility poles or distribution boxes, restricting site selection (e.g., deep in parks, rooftops).
- Solar + battery power is highly weather-dependent. Continuous rainy days (>3 days) lead to power outages, and battery capacity drops sharply at low temperatures (only 50% of normal capacity at -10℃).
- Short battery life (usually 7-15 days) and frequent replacements increase maintenance burdens. In a community project, 30% of stations had 5-10 days of missing data per month due to delayed battery replacement.
Lack of Installation Standards Causes Data Deviation
There are no unified standards for the installation height and orientation of micro stations:
- While standard stations require 1.5-15 meters above the ground, some micro stations are conveniently mounted on 1-meter-high light poles, making them susceptible to ground dust.
Facing upwind directions results in low pollutant concentrations collected by air inlets, leading to data distortion.